- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
HDR-150-24
product detail
Model meaning
HDR-150-24 | Model meaning |
HDR? | Switching power supply development code: DR: Guide rail basic type MDR: Guide rail plastic case type NDR: Guide rail small size type HDR: Guide rail economical plastic case type |
150 | Rated power: 15W 30W 45W 60W 75W 100W 120W 150W 240W 480W |
24 | Output DC voltage: 5V 12V 15V 24V 36V 48V |
Features
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
Technical parameters
model | HDR-150-12 | HDR-150-15 | HDR-150-24 | HDR-150-48 | ||
output | DC voltage | 12V | 15V | 24V | 48V | |
Rated current | 115VAC | 10.2A | 8.55A | 5.31A | 2.72A | |
230VAC | 11.3A | 9.5A | 6.25A | 3.2A | ||
Rated power | 115VAC | 122.4W | 128.3W | 127.4W | 130.6W | |
230VAC | 135.6W | 142.5W | 150W | 153.6W | ||
Ripple and Noise (Max) Note 2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | ||
Voltage adjustment range | 10.8~13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2~55.2V | ||
Voltage accuracy note 3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||
Linear adjustment rate | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
load regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
Start-up and rise time | 500ms, 60ms/230VAC 500ms, 60ms/115VAC (at full load) | |||||
Hold time(Typ.) | 30ms/230VAC 12ms/115VAC (at full load) | |||||
enter | voltage range | 85 ~ 264VAC (277VAC available) 120 ~ 370VDC (390VDC available) | ||||
frequency range | 47 ~ 63Hz | |||||
Efficiency(Typ.) | 0.89 | 0.895 | 0.905 | 0.905 | ||
AC current(Typ.) | 3A/115VAC??????1.6A/230VAC | |||||
Inrush current(Typ.) | Cold start 35A/115VAC 70A/230VAC | |||||
Protect | overload | 105 ~ 135% rated output power | ||||
When the output voltage is The output voltage is in constant current mode at 50% ~ 100%, and can automatically recover after the abnormal load condition is removed. | ||||||
Overvoltage | 14.2~16.2V | 18.8 ~ 22.5V | 30~36V | 56.5 ~ 64.8V | ||
Protection mode: shut down the output and can be restored after the power is restarted | ||||||
environment | working temperature | -30 ~ +70℃ (please refer to "Derating Curve") | ||||
Working humidity | 20 ~ 90% RH non-condensing | |||||
Storage temperature and humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||
temperature coefficient | ±0.03%/℃ (0 ~ 45℃) RH non-condensing | |||||
Vibration resistant | 10 ~ 500Hz, 2G 10 minutes/cycle, X, Y, Z each 60 minutes; installation: in line with IEC60068-2-6 | |||||
Operating altitude | 2000 meters (note 4) | |||||
Overvoltage level | Ⅲ;According to EN62368, EN61558, EN50178, EN60664-1, EN62477-1; Altitude up to 2000 meters | |||||
safety regulations and electromagnetic compatible (Note 7) | safety regulations | IEC62368-1, UL62368-1, UL61010, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, EACTPTC 004 certified; Design reference BS EN/EN50178, TUV BS EN/EN62368-1 | ||||
Pressure resistant | I/P-O/P:4KVAC | |||||
Insulation resistance | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
Electromagnetic compatibility emissions | Parameter | Standard | Test Level / Note | |||
Conducted | BS EN/EN55032(CISPR32) | Class B | ||||
Radiated | BS EN/EN55032(CISPR32) | Class B?(note 5) | ||||
Harmonic Current?(Note 6 ) | BS EN/EN61000-3-2 | Class A | ||||
Voltage Flicker | BS EN/EN61000-3-3 | ------- | ||||
Electromagnetic compatibility immunity | BS EN/EN55024, BS EN/EN61000-6-2 | |||||
Parameter | Standard | Test Level /Note | ||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact, criteria A | ||||
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3, criteria A | ||||
EFT/Burest | BS EN/EN61000-4-4 | Level 3, criteria A | ||||
Surge | BS EN/EN61000-4-5 | Level 4,2KV/L-N, criteria A | ||||
Conducted | BS EN/EN61000-4-6 | Level 3, criteria A | ||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, criteria A | ||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | ||||
other | MTBF | 3046.3K hrs min. Telcordia SR-332 (Bellcore) ; 535.9K hrs min. MIL-HDBK-217F (25℃) | ||||
size | 105*90*54.5mm (W*H*D) | |||||
Package | 0.31Kg; 32pcs/11Kg/1.0CUFT | |||||
Remark | 1. Unless otherwise specified, all specifications are measured at 230VAC input, rated load, and 25°C ambient temperature. 2. Ripple and noise measurement method: Use a 12" twisted pair cable with 0.1uf and 47uf capacitors connected in parallel at the terminal, and measure at 20MHZ bandwidth. 3. Accuracy: includes setting error, line regulation and load regulation. 4. Installation distance: When permanently loaded with full power, the recommended distance is 40mm at the top, 20mm at the bottom, and 5mm on both sides. If the adjacent device is a heat source, the recommended space distance is 15mm. 5. Output derating is required under low input voltage conditions. Please refer to the derating curve for details. 6. The power supply is considered as part of the system components and needs to be confirmed for electromagnetic compatibility in conjunction with the terminal equipment. Guidelines for EMC test methods, 7. When the altitude exceeds 2000 meters (6500 feet), the ambient temperature of the fanless model decreases at a rate of 3.5℃/1000m, and the ambient temperature of the fan model decreases at a rate of 5℃/1000m. |