- solid state relay
- Circuit Board Solid State Relay
- Single phase solid state relay
- Industrial Solid State Relays
- Three-phase solid state relay
- Three-phase forward and reverse solid state relay
- Rail type three-phase solid state relay
- Industrial grade solid state relay module
- Tension controller
- Intelligent voltage regulation module
- Single and three-phase silicon controlled trigger
- heat sink
- Semiconductor module, rectifier bridge series
- time relay
- Digital display counter
- water level controller
- timer
- switching power supply
- S series switching power supply
- MS series switching power supply
- LRS series switching power supply
- D, T, Q multi-group series switching power supplies
- DR rail series switching power supply
- NDR rail series switching power supply
- MDR rail series switching power supply
- HDR rail series switching power supply
- FY rainproof series switching power supply
- FS rainproof series switching power supply
- Foot switch
- Fan water pump controller
T-60B
product detail
Model meaning
T-60-B | Model meaning |
T | T: Three-way output |
60 | Rated power: 30W 50W 100W |
B | Output DC voltage: A:5V,+12V,-5V, B:5V,+12V,-12V, C:5V,+15V,-15V |
Features
High performance/price ratio
Pressure resistant and high efficiency
Quality is close to that of European and American products
Input AC power for global use
Small size, light weight, easy to install
The output has multiple protections for overcurrent, overvoltage and short circuit.
Can output 1-4 different voltages at the same time
Technical parameters
model performance | T-60A | T-60B | T-60C | T-60D | ||||||||
CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC output voltage | 5V 5A | 12V 2.5A | -5V 0.5A | 5V5A | 12V 2.5A | -12V 0.5A | 5V 5A | 15V 2A | -15V 0.5A | 5V? 3A | 12V 2A | 24V? 1A |
Ripple and noise | 50mvp-p | 100mvp-p | 50mvp-p | 50mvp-p | 100mvp-p | 100mvp-p | 50mvp-p | 100mVp-p | 100mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Incoming line stability | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% |
Load stability | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% |
efficiency | 78% | 79% | 79% | 80% | ||||||||
DC voltage Adjustable range | CH1:+10,-5% | CH1:+10,-5% | CH1:+10,-5% | CH1:+10,-5% | ||||||||
input voltage scope | 88~132VAC/176~264VAC selected by switch 47~63Hz: 240-370VDC | |||||||||||
Inrush current | Cold starting current 35A/230Y | |||||||||||
Overload protection | 105%~135% cut off output and automatically recover | |||||||||||
Overvoltage protection | CH1:5.75~6.75V | |||||||||||
start, rise hold time | 200ms,50ms,20ms | |||||||||||
Pressure resistance | Between input and output: 1.5KvAC, between input and shell: 1.5KvAC, between output and shell: 0,5KvAC for one minute | |||||||||||
Isolation resistor | Between input and output, between input and shell, between output and shell: 500VDC/100MΩ | |||||||||||
operating temperature, humidity | -10℃~ +60℃,20%~90%RH | |||||||||||
safety standards | Comply with GB49493, UL60950, EN60950 | |||||||||||
EMC standards | Comply with GB9254, EN55022 level A | |||||||||||
weight | 0.55kg |
Overall dimensions
Wiring location
Port 1.2: AC input
Port 3: Ground
Port 4: Secondary DC output V3
Port 5: Secondary DC output V2
Port 6: DC output COM
Port 7: Main DC output V1